24-head rotary tester designed with 3 test methods
Liquid and lyophilised vials 10R and 20R
The machine will be designed to test vial sizes from 2ml to 100ml
Testing capacity:
:vials per minute for 1 OR and 20R
Test capacity is also a function of test sensitivity. Test capacity and test sensitivity for larger sizes must be defined in further steps.
Test sensitivity for CCIT: 1O µm and larger can be detected for 1 OR and 20R, subject to testing with original products.
The test sensitivity for larger formats must be defined in further steps.
Crimp quality:
Crimp quality will affect test performance, due to possible air trapped in the crimp, causing false rejects.
Products must be completely dry on the outside before reaching the tester.
Using the needle valve and flow meter.
Power connection: 3 x 440V, 60Hz,
TN-S (Neutral! available), other power connections on request
Compressed air connection: :6 - 8 bar
Product handling: ln-line operation,
Tubular and moulded vial handling
Tor buffer table options with tray loading operation
A large screen is used as HMI, a colour touch panel! . The software uses 21 CFR part 11 guidelines. Various communication torpedoes are available for data transfer.
Details
- Industry:pharmaceutical, cosmetics, nutraceutical
- Inspect system:automatic
- Container type:Bottles / Vials
Conditions and size
- Status:Visible
- Condition:Good